安装lm-sensors出错解决方法



推荐点击下面图片,通过本站淘宝优惠价购买:

image.png

$sudo apt-get install lm-sensors

$ sensors

No sensors found!
Make sure you loaded all the kernel drivers you need.
Try sensors-detect to find out which these are.
这个原因是因为还没有配置好机器
解决方法:

$sudo sensors-detect 
一直yes就可以了
最后一项就可以看到有两行coretemp和w83627ehf(这个可能不同机器不一样)

 

 

$ sudo modprobe -v coretemp  insmod /lib/modules/3.2.0-27-generic-pae/kernel/drivers/hwmon/coretemp.ko   sheng@sheng:~$ sensors coretemp-isa-0000 Adapter: ISA adapter Physical id 0:  +40.0°C  (high = +82.0°C, crit = +102.0°C) Core 0:         +40.0°C  (high = +82.0°C, crit = +102.0°C) Core 1:         +40.0°C  (high = +82.0°C, crit = +102.0°C)  $ sudo modprobe -v w83627ehf  这样会出现 FATAL: Error inserting w83627ehf (/lib/modules/2.6.31-16-generic/kernel/drivers/hwmon/w83627ehf.ko): Device or resource busy

解决办法:

$sudo vi /etc/default/grub
GRUB_CMDLINE_LINUX="acpi_enforce_resources=lax"

修改grub文件,加入上面那句话。

$sudo update-grub
$reboot
重启后执行

$ sudo modprobe -v w83627ehf $ sensors  coretemp-isa-0000  Adapter: ISA adapter  Physical id 0:  +43.0°C  (high = +82.0°C, crit = +102.0°C)  Core 0:         +40.0°C  (high = +82.0°C, crit = +102.0°C)  Core 1:         +43.0°C  (high = +82.0°C, crit = +102.0°C)     nct6776-isa-0290  Adapter: ISA adapter  Vcore:         +0.97 V  (min =  +0.00 V, max =  +1.74 V)  in1:           +1.01 V  (min =  +0.00 V, max =  +0.00 V)  ALARM  AVCC:          +3.33 V  (min =  +2.98 V, max =  +3.63 V)  +3.3V:         +3.33 V  (min =  +2.98 V, max =  +3.63 V)  in4:           +1.02 V  (min =  +0.00 V, max =  +0.00 V)  ALARM  in5:           +2.04 V  (min =  +0.00 V, max =  +0.00 V)  ALARM  3VSB:          +3.41 V  (min =  +2.98 V, max =  +3.63 V)  Vbat:          +3.30 V  (min =  +2.70 V, max =  +3.30 V)  ALARM  fan1:            0 RPM  (min =    0 RPM)  ALARM  fan2:         2477 RPM  (min =    0 RPM)  ALARM  fan3:            0 RPM  (min =    0 RPM)  ALARM  fan4:            0 RPM  (min =    0 RPM)  ALARM  fan5:            0 RPM  (min =    0 RPM)  ALARM  SYSTIN:        +37.0°C  (high =  +0.0°C, hyst =  +0.0°C)  ALARM  sensor = thermistor  CPUTIN:        +84.5°C  (high = +81.0°C, hyst = +76.0°C)  ALARM  sensor = thermistor  AUXTIN:        +49.5°C  (high = +80.0°C, hyst = +75.0°C)  sensor = thermistor  PECI Agent 0:  +41.0°C    cpu0_vid:     +2.050 V  intrusion0:   OK  intrusion1:   ALARM


本文链接:https://www.hqyman.cn/post/4603.html 非本站原创文章欢迎转载,原创文章需保留本站地址!

分享到:





休息一下,本站随机推荐观看栏目:


« 上一篇 下一篇 »

发表评论:

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。

您的IP地址是: